FACTS ABOUT DP50RB REVEALED

Facts About Dp50rb Revealed

Facts About Dp50rb Revealed

Blog Article

1.2.two Warning Labels Warning Labels This means Please carefully read this handbook right before use unit. The next labels undoubtedly are a. Don't spot the device on a sloped surface. Or else the offered once the program unit could slide, resulting in individual injury or perhaps the unit functions Using the cell malfunction.

iZoom™ allows accurate viewing of graphic from distance iWorks™ Protocol allows standardize workflow and lessen Test instances

Simply click Concur and Move forward to simply accept cookies and go directly to the location or click Additional information to check out thorough descriptions of the categories of cookies and choose no matter if to simply accept specific cookies although on the site.

Observe: Make certain that you might pull out and drive in the IO board sockets vertically when pulling out and assembling the IO board assembly on the posture with the deal with. Eliminate panhead screws with washers M3X6 (four) used to safe the IO board, then you could acquire out the IO board. Website page 116 Get rid of panhead screws with washers (two M3X6) which can be set on the key device, consider out the upper baffle after which you can pull out two cables connecting the leading board to the facility module assembly.

The chapter materials the method to verify primary perform and performance of solution. That is only utilized for reference, not preventive execution. Perform examining and testing of the element shall be performed by Mindray assistance engineers along with the user together. Page sixty six: Normal Test

three. Click the upper icon within the monitor (prompts “Update” if you set the cursor on it), the update stage is completed, if fails, you should send out to R&D center. Determine 6-one Principal Keep an eye on Upkeep Display screen 4. Just after update is successful, restart the device after energy off to help make the information effective. HDD Partition ... Web site 91 structured report related facts file and DICOM viewing computer software Report report template obd.bin OBD data file Edition.txt Model file Remark Comment file AnatomyImage Anatomical illustrations or photos Measurement Measurement library Doppler application and relevant boot configuration most important file and plug-ins, distant desktop server Multilanguage string file exe videoplay.

Effectiveness Test five.5.1 Test Course of action Resolution Detection depth Geometric Situation Precision Blackout area examination Record the Test photos five.five.two Examination Material The image utilized Here's just for reference, stick with the image effect in the true Notice: condition. Requirements: Show: established the distinction and brightness for the scientific application value (or the default standing) Operation ecosystem: darkish place, simulating the clinical application environment. Web page seventy six In situation which the transverse resolution screening targets are horizontally shown, document the minimal length of two targets that could be clearly identified. Repeat the operation earlier mentioned for the transverse resolution testing targets at other depths. As revealed in figure below. Axial resolution ... Page 77 When using the convex probe, retain the transverse resolution tests targets to NOTE: be shown near the midline. When using a linear probe with steer perform, will not activate the steer functionality when complete the transverse resolution test. Zoom while in the location the place the targets Situated if required. The diameter in the target stage at a specific depth is equal for the transverse resolution on the depth. Webpage 78 5.

five.two.three Geometric positioning accuracy Longitudinal geometric positioning accuracy  Check Dp50rb Phase: Do adjustments as how in tests the maximum depth. Document the distance by 20mm Each individual segment on the longitudinal targets line using the measurement caliper; Select the worth with the best error (to 20mm), calculate the precision using the formula down below The measurement caliper needs to be positioned at the upper fringe of the goal, Take note:... Website page seventy nine Transverse geometric positioning accuracy  Exam Move: Cover the scan surface in the phantom with water or couple gel, gently Call the probe with the scan area Adjust the depth, making the transverse targets to get exhibited within the image. Adjust the main target point being posited beside the transverse targets (the typical is not really crystal clear) Alter parameters like attain, TGC, creating Just about every transverse targets to be clearly exhibited. Page 80 five.five.two.4 Blackout Place Test Action: Deal with the scan area of your phantom with water or few gel, Carefully Call the probe With all the scan surface area Alter the depth in a lower worth, and set the main focus at the closest destination to the scan area. Minimize the worth of parameters like AP, Get until finally the history sounds just is often seen. Site eighty one: Application Upgrade And Routine maintenance

Observe: Just before uploading the log, be certain the ultrasound process has become linked to network, in any other case, the technique could alert “couldn't connect to server” The server (smtp.

After changing the CPU module, vital file have to be produced Yet again in accordance with the new MAC handle and written into HDD in the machine. Or else, the configuration perform of the item is going to be misplaced. Just after taking away the CPU module, Remove panhead screws with washers (12 M3X6) fixed on the principle device box, you normally takes from the board. Page 118 Determine eight-29 Disassemble the Control Panel Assembly (1) Keep the upper fringe of user interface assembly, and open up up the user interface. Figure 8-thirty Disassemble the User interface Assembly (2) Just after eliminating a person countersunk head self-tapping screw PT3X10 fastened within the user interface and get out the plug of your keyboard and the primary unit connecting cables, you can eliminate the user interface assembly.

After you end the scanning and the impression seize, you ought to energy off the technique and disconnect the procedure through the AC ability source, then pull out AC power cables. Web page 109: Battery Connecting Board

This manual could referring to facts secured by copyright or patents and isn't going to Express any license under the patent legal rights or copyright of Mindray, or of Other people. Web site nine: Statement

Slice off cable ties connecting the most crucial unit around the Show by diagonal cutting pliers, and then pull out the corresponding cable plugs.

Be aware: Within the keep track of, the brightness adjustment comes before distinction. Immediately after readjusting the check’s distinction and brightness, adjust all preset and peripheral options.